Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
2.
Arch. cardiol. Méx ; 91(1): 73-83, ene.-mar. 2021. graf
Article in Spanish | LILACS | ID: biblio-1152863

ABSTRACT

Resumen Antecedentes: El conducto arterioso permeable (CAP) es un defecto cardiaco congénito y se considera un problema de salud pública. Se presenta en un alto porcentaje de recién nacidos y en algunos mayores de 1 mes. El cierre farmacológico es el tratamiento inicial preferido, ya que ha tenido excelentes resultados; sin embargo, en aquellos casos en los que no es posible, está indicado el cierre quirúrgico. Objetivo: Evaluar la eficacia y la seguridad del cierre quirúrgico del CAP por cirujanos pediatras sin especialidad en cirugía cardiovascular. Método: Ensayo clínico realizado en pacientes del Hospital General de Occidente, centro hospitalario público de segundo nivel, con diagnóstico de CAP, que requirieron corrección quirúrgica. Se revisaron en forma retrospectiva los expedientes de enero de 2001 a diciembre de 2018. Resultados: Se incluyeron 224 pacientes divididos en dos grupos: grupo I, con 184 (82%) recién nacidos, y grupo II, con 40 (18%) niños grandes de 2 meses a 8 años de edad. A todos se les realizó cierre quirúrgico: 3 por toracoscopía y 221 por toracotomía posterolateral izquierda. Presentaron complicaciones 36 pacientes, lo que representa el 16% del total; solo el 5.3% fueron complicaciones mayores. Fallecieron 24 pacientes en el posoperatorio, lo que representa una mortalidad del 10.7%; ninguno falleció por complicaciones transquirúrgicas. El CAP es un defecto cardíaco congénito que se presenta en alto porcentaje en pacientes prematuros. El cierre farmacológico es el principal tratamiento por tener excelentes resultados en recién nacidos; sin embargo, en aquellos casos en los que no sea posible está indicado el cierre quirúrgico. Todos los pacientes fueron operados por cirujanos pediatras generales, con una sobrevida global del 92%. Conclusiones: En los hospitales donde no hay cirujano cardiovascular pediátrico ni cardiólogo intervencionista, la corrección quirúrgica del CAP puede ser llevada a cabo por un cirujano pediatra. La técnica es reproducible, fácil de realizar y con mínimas complicaciones.


Abstract Background: The Patent Ductus Arteriosus (PDA) is congenital heart defect and is considered a public health problem. It occurs in a high percentage of newborns and in some older than 1 month. Pharmacological closure is the preferred initial treatment, as it has had excellent results; however, in those cases where it is not possible, surgical closure is indicated. Objective: The objective is to evaluate the efficacy and safety of the surgical closure of the patent PDA when it is carried out by pediatric surgeons without specialization in cardiovascular surgery. Methods: This study was conducted at the West General Hospital, a 2nd level public hospital, with the diagnosis of patent ductus arteriosus that required surgical correction. For the collection of the information, the files from January 2001 to December 2018 were retrospectively reviewed. Results: 224 patients were included; divided into two groups: Group I: 184 (82%) "newborns" and Group II: 40 (18%) "big children" with ages from 2 months to 8 years. All had a surgical closure; 3 by thoracoscopy and 221 by left posterolateral thoracotomy. 36 patients presented complications representing 16% of the total of patients, only 5.3% were major complications. 24 patients died in the postoperative period, representing a mortality of 10.7%, none died due to trans-surgical complications. PDA is a congenital heart defect that occurs in a high percentage of premature patients. The pharmacological closure is the principal treatment because it has had excellent results in newborns; however, in those cases where it is not possible, surgical closure it´s indicated. All patients were operated by general pediatric surgeons, with a global survival of 92%. Conclusions: We conclude that in hospitals where there is no pediatric cardiovascular surgeon or interventional cardiologist, the surgical correction of the PDA can be carried out by a general pediatric surgeon. The technique is reproducible, easy to perform and with minimal complications.


Subject(s)
Humans , Male , Female , Infant, Newborn , Infant , Child, Preschool , Child , Ductus Arteriosus, Patent/surgery , Cardiac Surgical Procedures/adverse effects , Pediatrics , General Surgery , Retrospective Studies , Treatment Outcome
4.
Arch. cardiol. Méx ; 90(3): 336-340, Jul.-Sep. 2020.
Article in Spanish | LILACS | ID: biblio-1131052

ABSTRACT

Resumen La cardiología pediátrica y la cirugía cardiovascular han tenido avances importantes en los últimos años; las cardiopatías congénitas (CC) son una de las principales causas de mortalidad en niños. Muchos de los factores que determinan la evolución final de estos pacientes incluyen el tipo de cardiopatía y el tiempo del diagnóstico y tratamiento; infortunadamente, dos de los que presentan mayores efectos son el estado socioeconómico y el área geográfica de atención en México. El objetivo de este estudio es conocer el tipo de atención para los pacientes con CC en hospitales públicos del país.


Abstract Pediatric cardiology and cardiovascular surgery have made significant advances in recent years, congenital heart diseases (CHD) are one of the leading causes of mortality in children. Many of the factors that determine the final evolution of these patients include the type of heart disease, the time of diagnosis and treatment; unfortunately, in our country, two of those greatest impact area the socioeconomic status and the geographic area of attention. The objective of this study is to know the type of care for patients with CHD in public hospitals in the country.


Subject(s)
Humans , Child , Healthcare Disparities , Heart Defects, Congenital/therapy , Hospitals, Public/standards , Socioeconomic Factors , Right to Health , Heart Defects, Congenital/diagnosis , Mexico
5.
Arch. cardiol. Méx ; 90(2): 124-129, Apr.-Jun. 2020. tab
Article in English | LILACS | ID: biblio-1131020

ABSTRACT

Abstract Introduction: Congenital heart disease represents a public health issue worldwide. Objective: To know the number of patients with heart disease treated in two public hospitals of the State of Jalisco, as well as the mortality and resources available to participating hospitals for the care of these patients in the period from 2015 to 2018; the information was requested to the National Transparency Platform, and the database of pediatric cardiology services and pediatric cardiovascular surgery of the participating hospitals were also reviewed. Results: The second level hospital has human resources, but not the material to attend to these patients; so it is not possible to offer any type of palliative or corrective treatment. A total of 624 patients were evaluated, of which 92.2% corresponded to non-critical heart disease; overall mortality was 12% but in critical heart disease it was 79.5%. The third level hospital has human and material resources to care for these patients. During the study period, 289 operations were performed and the overall mortality was 20.4%. Conclusion: Congenital heart disease in the State of Jalisco is an important cause of mortality, with a high incidence and a very limited resolution capacity since the health services in the State of Jalisco for the care of these patients are insufficient and inadequate. It is essential to strengthen the health system for the care for these patients.


Resumen Introducción: Las cardiopatías congénitas representan un problema de salud pública a nivel mundial. Objetivo: Conocer la cantidad de pacientes cardiópatas atendidos en dos hospitales públicos del estado de Jalisco, así como la mortalidad y los recursos con que cuentan los hospitales participantes para la atención de estos pacientes en el período del 2015 al 2018. Se solicitó la información a la Plataforma Nacional de Transparencia y además se revisaron las bases de datos de los servicios de cardiología pediátrica y cirugía cardiovascular pediátrica de los hospitales participantes. Resultados: El hospital de segundo nivel cuenta con los recursos humanos, pero no con el material para atender a estos pacientes, por lo que no es posible ofrecer ningún tipo de tratamiento paliativo o correctivo (sólo se cierran algunos conductos arteriosos en la etapa neonatal). Se valoró a un total de 624 pacientes, de los cuales el 92.2% correspondió a cardiopatías no críticas; la mortalidad global fue del 12% pero en las cardiopatías críticas fue del 79.5%. El hospital de tercer nivel cuenta con recursos humanos y material para atender a estos pacientes; en el período de estudio se realizaron 289 operaciones y la mortalidad global fue del 20.4%. Conclusión: Las cardiopatías congénitas en el estado de Jalisco son una causa importante de mortalidad, con una incidencia elevada y una capacidad de resolución sumamente limitada, ya que los servicios de salud de Jalisco para la atención de estos pacientes son insuficientes e inadecuados. Es esencial fortalecer el sistema de salud para atender a estos pacientes.


Subject(s)
Humans , Infant, Newborn , Infant , Child, Preschool , Delivery of Health Care/organization & administration , Health Resources/statistics & numerical data , Heart Defects, Congenital/therapy , Prospective Studies , Heart Defects, Congenital/mortality , Heart Defects, Congenital/epidemiology , Hospitals, Public , Mexico
6.
Arch. cardiol. Méx ; 89(2): 172-180, Apr.-Jun. 2019. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1142179

ABSTRACT

Resumen Introducción y objetivos: En algunos centros el tamiz cardíaco no se realiza con la justificación de no tener el oxímetro adecuado. Comparamos la efectividad de dos marcas de oxímetros para realizarlo. Métodos: En los neonatos a término del Servicio de alojamiento conjunto del Hospital General de Occidente en Zapopan Jalisco México de mayo a noviembre del 2018 se realizó tamiz cardíaco según las guías de la Academia Americana de Pediatría con dos oxímetros, el Masimo SET (aprobado por la FDA) y el ChoiceMMed, comparando su efectividad para la detección de cardiopatías congénitas críticas, el tiempo de toma y los falsos positivos. Resultados: En cada grupo se analizaron 1,022 pacientes; con el oxímetro Massimo SET se obtuvieron 83 pruebas positivas (8.12%) de las cuales 22 casos presentaron alguna cardiopatía (26.5%), lo que representa una sensibilidad del 100%, una especificidad del 93.9%, un valor predictivo positivo del 26.5% y un valor predictivo negativo del 100% (Odd Ratio [OR]: 0.73; IC 95%: 0.6-0.8). Con el oxímetro ChoiceMMed se obtuvieron 168 pruebas positivas (16.4%), de las cuales 22 casos presentaron alguna cardiopatía (13.09%), con una sensibilidad del 100%, una especificidad del 85.4%, un valor predictivo positivo del 13.09% y un valor predictivo negativo del 100% (OR: 0.86; IC 95%: 0.8-0.92). En cuanto al tiempo para realizar el tamiz cardíaco, la media en minutos del oxímetro Masimo SET fue 5.38 y del oxímetro ChoiceMMed fue 9.7 minutos. Conclusiones: El oxímetro ChoiceMMed presentó mayor cantidad de falsos positivos y mayor tiempo de realización del tamiz cardíaco en comparación al Masimo SET, sin embargo, ambos presentan un valor predictivo negativo del 100%, siendo igualmente útiles como método de detección de cardiopatías críticas.


Abstract Introduction and objectives: In some centers the pulse oximetry is not performed with the justification of lack of the adequate oximeter. We compared the effectiveness of two brands of oximeters to perform it. Methods: In neonates a term of the joint housing service of a Hospital General de Occidente in Zapopan Jalisco Mexico from May-November 2018, an examination of the characteristics of the American Academy of Pediatrics with both oximeters (ChoiceMMed and Masimo SET) was carried out, comparing the detection of critical congenital heart disease (CCC), time of intake and false positives. Results: In each group 1,022 patients were analyzed; with the Masimo SET oximeter 83 positive tests were obtained (8.12%), of which 22 cases had some heart disease (26.5%), which represents a sensitivity of 100%, specificity of 93.9%, positive predictive value of 26.5% and negative predictive value of 100% (OR: 0.73; 95% CI: 0.6-0.8). With the ChoiceMMed oximeter, 168 positive tests were obtained (16.4%), of which 22 cases had some heart disease (13.09%), with a sensitivity of 100%, specificity of 85.4%, positive predictive value of 13.09% and negative predictive value 100% (OR: 0.86; 95% CI: 0.8-0.92). Regarding the time to perform the cardiac sieve, the mean in minutes of the Masimo SET oximeter was 5.38 and the ChoiceMMed oximeter was 9.7 minutes. Conclusions: The ChoiceMMed oximeter contains a large number of false positives and a greater number of echocardiograms and comparatively longer cardiac screen printing with Masimo SET, however, both with a negative predictive value of 100% eliminating such excuses.

SELECTION OF CITATIONS
SEARCH DETAIL